MUS0920201
07/10/2014 58
MELTON, S.L.U. - POLIGONO INDUSTRIAL AGUSTINOS CALLE G-34,31160 ORCOYEN, NAVARRA
TEL: 00 34 948 321580 Fax: 00 34 948 326584 e-mail: [email protected]
6.3. MAINTENANCE PROCESSES:
6.3.1. PUMP REPLACEMENT
Follow these steps to replace the pump:
1. Make sure the machine is off.
2. Remove the bench cover by releasing the screws with an Allen wrench.
3. Release the pump coupling. Remove the two set screws with an Allen
wrench in order to do so.
4. Release the four Allen screws.
5. Position the new pump and follow the above process in reverse order.
Apply a torque of 43 N·m