A.2.4. ELECTRICAL WIRING
The solenoid valve must be connected to a 0-24 VDC activation signal on the main
machine.
A.2.5. PNEUMATIC CONNECTION
The regulator features a pneumatic connection for a Ø8 tube.
It is situated on the regulator with the pressure gauge.
At least 6 bars of pressure are necessary.
A.3. MACHINE ADJUSTMENTS
A.3.1. INTRODUCTION
Before operating the machine, you must read the manual and understand it in
order to ensure the proper, safe operation of the unit.
The operator must do a series of movements in order to start the application.
The adhesive temperature is controlled by the feeder (see the corresponding
manual).
A.3.2. PRESSURE CONTROL
The depressurisation valve features a pressure ratio of 15:1. This means that for
each bar of pressure on the pressure gauge, there are 15 bars of pressure in the
manifold outlet.
Unlock the regulator. To do so, pull the grip until the orange edge appears.
Adjust the regulator to the desired pressure.
Lock the regulator. Push the grip. If it does not lock easily, turn slightly to the left
and to the right and place pressure on it. The orange edge should disappear.
A.3.3. TURNING THE UNIT ON
The unit is activated with a 0-24VDC signal.