4.3.2.4. Ready delay Time
It is found under the settings / system / time before start menu.
When using the Ready Delay Time option, the system ready LED will turn on at a
pre-set time after all of the zones reach the respective programmed temperatures
except for the system ready compensation temperature. This feature allows the
adhesive in the system to heat up for an additional time before the pump motor
activates.
Once the set temperature has been reached, the time remaining before the
machine is ready is shown in a status bar at the bottom of the screen.
The times range from 1 minute to 120 minutes. It is factory set ON with a time of
15 minutes.
To extend the life of the pump joints, this 15 minute time should not be reduced.
You can access this parameter with a password level of 2 or higher.
4.3.2.5. Over Temperature Alarm
It is found under the settings / system / overheat menu.
The Over Temperature Alarm refers to the temperatures set for each machine
zone.
The tolerance for the overheat alarm is the number of degrees that each zone has
heated above the set temperature before the alarm goes off.
If any zone enters in the overheat alarm zone, this zone automatically stops
heating.
The alarm tolerance range is 9ºF to 108ºF (5ºC to 60ºC). It is factory set at 45º F
(25º C).