4.3.4. DIAGNOSIS:
This is found under the settings / diagnosis menu.
The diagnostics screen displays the current software version as well as the current
temperature and status of each zone.
4.3.5. SETBACK TEMPERATURE / TIME:
This is found under the settings / setback menu.
The setback time option is used to reduce the temperature of all of the zones with
a temperature difference where the hot-melt is soft but does not melt. It is used when
the machine is not in use.
The temperature differential is related to the programmed temperature for each
zone.
The temperature differential has a range of 45ºF to 342ºF (25ºC to 190ºC). The
default value is 90ºF (50ºC).
You can access this parameter with a password level of 2 or higher.
The stback standby time is the time it takes the machine to enter into setback
mode.
Remember to enable the setback standby time by pressing the switch.
If the automatic standby time at setback option is enabled and there is no external
unit connected to the machine, the machine will automatically go into setback mode
once the programmed time has passed.
If the automatic standby time at setback option is enabled and there is an external
unit connected to the machine, the machine will automatically go into setback mode
once the programmed time has passed as long as it does not receive any pulse from the
external machine. If it does, the standby time at setback will begin at zero.
The standby time at setback range is 1 minute to 120 minutes. It is factory set at
30 minutes.