MELTON, S.L.U. - POLIGONO INDUSTRIAL AGUSTINOS CALLE G-34,31160 ORCOYEN, NAVARRA
TEL: 00 34 948 321580 Fax: 00 34 948 326584 e-mail: [email protected]
4.8. DRY AIR SYSTEM:
The equipment has a pneumatic system to maintain the tank pressurized at 0,3
bar with dry air or N
2.
When the lid is closed the equipment eliminates the warm air of the tank and
introduces dry air or N
2
.
When using nitrogen remove the dryer and the filters to prevent nitrogen loss.
This system is independent from the rest although the equipment is off.
To actívate it use the dry air selector.
Always the adhesive used is PUR it’s necessary to maintain the
dry air system on to prevent the crosslinking of the adhesive.