A.75
Addendum
Motor and Circuit Protective Devices
Manual Page Number
Revision
Impeller Motor Heater
Elements
for NEMA motor
size 4 starter
40 H.P., 200-240 volts
Across-the-Line Start
Motor Full
Load Amps
(see motor
information
plate)
Full Load Amps
for
Wye-Delta Start
(dial setting on
overload relay)
Overload
Relay
(OL1)
Part
Number
50
29.0
12834
51
29.6
12834
52
30.2
12834
53
30.7
12834
54
31.3
12835
55
31.9
12835
56
32.5
12835
57
33.1
12835
58
33.6
12835
59
34.2
12835
60
34.8
12835
61
35.4
12835
62
36.0
12835
63
36.5
12835
64
37.1
12835
65
37.7
12835
66
38.3
12835
67
38.9
12835
68
39.4
12835
69
40.0
12835
70
40.6
12835
71
41.2
12835
72
41.8
12835
73
42.3
12837
74
42.9
12837
75
43.5
12837
76
44.1
12837
77
44.7
12837
78
45.2
12837
79
45.8
12837
80
46.4
12837
81
47.0
12837
82
47.6
12837
83
48.1
12837
84
48.7
12837
85
49.3
12837
86
50.0
12837
87
50.5
12837
Motor
Full
Load
Amps
Heater Element
Size 4 Starter
Part No. Description
90 63374 W76
91 63374 W76
92 63374 W76
93 63374 W76
94 63374 W76
95 63374 W76
96 63374 W76
97 63374 W76
98 63374 W76
99 63375 W77
100 63375 W77
101 63375 W77
102 63375 W77
103 63375 W77
104 63375 W77
105 63376 W78
106 63376 W78
107 63376 W78
108 63376 W78
109 63376 W78
Motor Full
Load Amps
(see motor
information
plate)
Overload
Relay
34—40
12835
60 — 63
12838
64 —69
12839
Impeller Motor
Overload Relays
for IEC contactors,
Across-The-Line Start
Impeller Motor Overload Relays
for IEC contactors, Wye-Delta Start
The chart below shows the motor full load amps
(first column) and the calculated value for Wye-
Delta start (second column). To calculate this
value, the full load amp rating of the motor is
multiplied by .58. This value is used to determine
the overload relay used. For example, 60 (FLA) x
.58=34.8. From the second column in the chart,
see the value 34.8 and select 12835 overload
relay. The overload relay has a dial on the front
that must be set to the calculated amp value.
70–83 Parts,
Electrical Assembly
,
continued:
repair parts for previous electrical
assembly and enclosure.
Summary of Contents for COMITROL 2100
Page 2: ......
Page 28: ...Addendum A 26 This page intentionally left blank...
Page 84: ...6 This page intentionally left blank...
Page 94: ...16 This page intentionally left blank...
Page 95: ...17 GENERAL INFORMATION...
Page 101: ...23 INSTALLATION...
Page 104: ...26 This page intentionally left blank...
Page 110: ...32 This page intentionally left blank...
Page 131: ...53 PARTS...
Page 132: ...54 This page intentionally left blank...
Page 134: ...56 PARTS Tools See the Addendum for updated information...
Page 138: ...60 PARTS Agitator Feed Screw See the Addendum for updated information...
Page 146: ...PARTS Motor and Drive Parts 68 See the Addendum for updated information...
Page 148: ...PARTS Electrical Assembly NEMA 70 See the Addendum for updated information...
Page 152: ...PARTS Electrical Assembly CE compliant 74 See the Addendum for updated information...
Page 156: ...78 PARTS Electrical Assembly Switches See the Addendum for updated information...
Page 165: ......