Troubleshooting and Maintenance
57
Document Number 206465-0001
User Guide
11. Use the 7/64 T-Handle to hold pressure against the toggle spring and keep the idler wheel away from
the material. Remove the 1/8 T-Handle.
12. Press
Blower Off
on the interface panel. With the head blower off the temperature of the extrusion
tube will increase.
13. After approximately 5 seconds, reduce pressure against the toggle spring and allow the idler wheel to
contact the material. Material should extrude from the clogged tip.
Note:
The blower will automatically turn on after 10 seconds.
14. Press
Stop
on the interface panel.
15. Move the toggle bar to activate the drive wheel control options for the non-clogged side.
16. Press
Forward
on the interface panel. Make sure that material extrudes from the non-clogged extru-
sion tip.
Note:
It is necessary to confirm proper operation of the non-
clogged side. Temporarily having the blower off can
occasionally cause the non-clogged side to clog.
17. Press
Stop
on the interface panel.
18. Install air plenum.
19. Install plastic head cover.
20. Exit Maintenance mode.
Recovering From Loss of Extrusion
Note:
It is recommended that you read and understand this entire
procedure before performing any of the work.
1. Enter
Head Maintenance
mode.
A. From
Idle
, press
Maintenance
.
B. Press
Next
.
C. Press
Head Maintenance
.
Summary of Contents for 180-00108 uPrint