Pag. 5
DUALCOM-8 INSTALLATION MANUAL
ENGLISH
TERMINAL
BLOCK
DISCRIPTION
JUMPER
DISCRIPTION
LED
DISCRIPTION
OTHER
DISCRIPTIONS
Terminal
Description of function
33-35
DRY CONTACT RELAY OUTPUTS (IN ALARM):
33
=Normally open;
34
= Common;
35
= Normally closed.
36-37
SIREN OUTPUT:
36
= +12V (in alarm);
37
= GROUND
38-39
PTC PRO12Vdc POWER OUTPUT:
38
= +12V;
37
=GROUND
40-41
SWITCHING POWER SUPPLY INPUT:
40
= + 14.8Vd.c. ;
41
=GROUND
42
MICRO USB PORT
JUMPER
Discription and functions
43
IF BRIDGE IS “ON”, TERMINAL 34 WILL HAVE +13.8 Vdc.
54
CONTROL PANEL NORMALLY CLOSED TAMPER SWITCH= WHEN OPEN,
AN IMMEDIATE TAMPER TRIGGER WILL TAKE PLACE.
56
RESET JUMPER: IF THIS JUMPER IS INSERTED FOR 10 SECONDS, THE CON-
TROL PANEL WILL AUTOMATICLY RETURN TO FACTORY DEFAULT
LED
Description and functions
47
GSM COMMUNICATION LED: IF “ON” = INITIALIZATION TAKING PLACE
IF “FLASHING” = FUNCTIONING NORMALLY
IF “OFF” = INDICATES MALFUNCTION
52
CPU LED: IF “ON” = INITIALIZATION TAKING PLACE
IF “FLASHING” = NORMAL FUNCTIONING MODE
IF “OFF” = INDICTES MALFUNCTION
55
COMUNICATION LED : IF “ON” = INITIALIZATION TAKING PLACE
IF “FLASHING” = NORMAL FUNCTIONING MODE
IF “OFF” = INDICATES MALFUNCTION
Other
Description and functions
44
BATTERY CHARGING CABLE
45
BATTERY PROTECTION FUSE: 3.15Amp.
46
SIM CARD SOCKET
48
SMA CONNECTOR FOR GSM ANTENNA
49
MICROPHONE FOR THE RECORDING OF VOICE MESSAGES
50
LOUD SPEAKER CONNECTOR FOR MESSAGE PLAYBACK
51