Pag. 61
DUALCOM-8 INSTALLATION MANUAL
ENGLISH
99 Return the control panel to factory setting
In this section is described how the control panel may be totally reset to the factory values.
In the programming menu press the digits:
On the Display appears:
The control panel will automatically be returned to it original factory settings and all memories will be
canceled..
GENERAL CARACTERISTICS
:
∗
Mains power: 230 Vac. +/- 10% (50Hz)
∗
D.C. power: 13.5 –14.4 Vdc. 1600 mA
∗
Current drain: 250 mA
∗
Maximum current drain: 400 mA
∗
Minimum guaranteed R.F. transmission range: 30 meters
∗
Working frequency: 433.92 Mhz
∗
On board GSM module: QUECTEL M10
∗
R.F. on board transceiver:
(Tre I systems custom built) GW TRANSK 1120
®
∗
Change over relay: I max=1 A
∗
Programmable input response time: 0- 55 / 1-250 / 2-500 / 3-750 ms
∗
Working Temperature: from –10°C to +50°C
∗
Technology: SMD
∗
Dimensions: ABS Housing (275x220x80 mm.) - Steel Housing (310x315x80 mm.)
∗
Weight with steel housing (without battery): 4.9 Kg.
∗
Weight with ABS housing (without battery): 1.2 Kg.
【
】+【
99
】+【#】
System reset
F