DUALCOM-8 INSTALLATION MANUAL
ENGLISH
03. Management of the hardwire zones
In this section you will find how the hardwire zones must be managed.
Note: With the Dualcom-8 control panel, it is possible to have a minimum of 8 and a maximum of 24
hardwire zones by adding the expansion module EZ-8. With the on-board program, it is possible to
manage all 24 zones even if the EZ-8 expansion module is not installed by pressing the following
digits on the keypad. (see section A on page 62).
On the display appears:
In this mode the hardwire zones may be programmed with the following characteristics: Each number
below from 1 to 10 corresponds to a function. See design on page 19 section 03.01
1. Select alarm type (Burglary-Fire-Hold-up)
2. Zone with 24 hour trigger feature -(always armed)
3. Zone with immediate or delayed trigger
4. Type of siren (see design on section 03.01)
5. Type of sound emitted by the siren
6. Alarm trigger signal from keypad buzzer
7. Arming in DAY / NIGHT
8. Input RESPONSE TIME
9. Select contact trigger type (normally open or normally closed)
10. Select the area in which the zone must function. (Area 1 or Area 2)
You may flow through the menu by pressing the keys seen below:
To go to the previous page.
To go to the next page.
【
】+【
03
】+【#】
Wired Zone
F