Pag. 58
DUALCOM-8 INSTALLATION MANUAL
ENGLISH
15 Visualizing the alarm event log
In this section is described how to visualize the alarm trigger event log
In the programming menu mode digit:
On the Display will appear:
In this mode you may:
1. Visualize the last 50 alarm trigger events
NOTE: It is possible to memorize up to 50 alarm trigger events. Every new event over the 50,
will automatically cancel the older events memorized.
In the menu “alarm record” press the digits:
【
01
】
+
【
#
】
or flow up and down in the menu with the
keys:
【
】
or
【
】
On the Display appears:
On the above display window is shown that the Dualcom-8 has memorized an alarm trigger on
12 January at 15:30 in zone 1.
【
】+【
15
】+【#】
Alarm record
Alarm record
<01> 0101121530
Description
Note
Zone
01 -72 .In this
case
zone 01
Month
01 -12. In this
case
January
Day
01- 31. In this
case
12
.
Hour
00 -23. In this
case
15
Minutes
00-59. In this
case
30
Position.
In this case the last alarm
trigger.