Pag. 25
DUALCOM-8 INSTALLATION MANUAL
ENGLISH
05.01 Management of zone 1 for the alarm trigger transmission
In the menu for the management of the zone alarm transmission, press the digits
【
01
】
+
【
#
】
or
flow up and down in the menu with the keys:
【
】
or
【
】
On the Display appears:
After you are sure that all the alarm transmission function are okay, set the parameters and press the
key
【
#
】
to confirm. In case of doubt it is best to repeat the control panel sequence rather then
risk panel malfunction.
Example of how to program:
Zone 1 must be programmed as follows:
1. (1) Transmit the alarm to the first telephone number
2. (1) Transmit the alarm to the second telephone number
3. (1) Transmit the alarm to the third telephone number
4. (0) No alarm transmission to the fourth telephone number
5. (1) Transmit the alarm to the fifth telephone number
On the Display appears:
To confirm press the key
【
#
】
.
05.02-24 Management of the remaining zones 2 to 24 for the telephone alarm transmission
Proceed with the programming as indicated in section 05.01. You must enter into programming
mode by pressing the keys:
【
(02-24)
】
+
【
#
】
or flow with up/down with the keys
【
】
or
【
】
Wired report
<01>11101
TRANSMISSION OF THE ALARM TO:
(1)
First number
0=no transmission
[1]
= transmit
(2)
Second number
0=no transmission
[1]
= transmit
(3)
Third number
0=no transmission
[1]
= transmit
(4)
Forth number
[0]
= no transmission
1=transmit
(5)
Fifth number
0=no transmission
[1]
= transmit
ZONE no.
Wired report
<01>11101