Pag. 12
DUALCOM-8 INSTALLATION MANUAL
ENGLISH
01.01 To change the existing password
In the principle menu of the password management, press the digits:
【
01
】
+
【
#
】
on the display will
appear the factory Installed code:
To change the password, you must digit a number with 6 figures from 0 to 9, and then press
【
#
】
to
confirm. The keypad will emit a series of beeps.
The factory installed password is:
Example: If you wish to install a new code 654321; Press on the keypad (654321#)
01.02 Level of security and password of Operator 1
In the principal menu of the password management, press the digits
【
02
】
+
【
#
】
on the
display
will appear: Note: Operator 1 corresponds to 2, Operator 2 corresponds to 3 etc.
To change the security level and password of operator 1, you must press the keypad number that
corresponds to the security level followed by the password of 4 figures and confirm with the key
【
#
】
The first number pressed will refers to the level of security desired. See below the levels available:
-0- Operator that has
NO FUNCTION
. (No function level)
-1- Operator can only
DISARM
the control panel.
-2- Operator can only
ARM
the control panel.
-3- Operator can only
ARM
and
DISARM
AREA 1
-4- Operator can only
ARM
and
DISARM
AREA 2
-5- This Operator can operate all the functions of the control panel:
HE MAY ARM OR DISARM, BY-PASS ZONES, ARM and DISARM ZONES BY-PASSED
EXAMPLE: If we want that the operator 1 be in level 4 with the password 1234; you must digit on the
keypad 41234#
0
1
2
3
4
5
Password
<01>012345
Password of 4 figures (in this case
0000 is factory installed)
.
Level of security is
5
(see 5 below)
This is the maximum security level.
Password
<02>50000
Operator
(in this case no.
1
)