Message
:
Unable to Run
PTP clock is not created on Initiator.
Meaning
:
This is a PTP validation error. If PTP is not created and RFC2544 latency is chosen
and you run the test, this error displays and the RFC2544 latency test will not run.
Recovery
:
1. Configure a PTP clock instance to ensure accurate RFC 2544 Latency test step timestamps.
2. Make sure PTP is running on both devices to synchronize the Time of Day. See “
PTP Clock
Configuration
” on page
316
.
3. Retry the operation. See the RFC 2544 User Guide for more
RFC2544 latency test
information.
Message
:
Insufficient Privilege Level The web page is non-accessible. Please use the valid privilege
level.
Meaning
: Issue with privilege level after login with using a user configured with level 15.
A configured user is allowed to login if is the only login method for HTTP or SSH.
Saving the configuration and rebooting after configuring will allow the correct authentication.
Only authenticated users can login after reboot.
Recovery
:
1. Save and reboot after adding a configuration change.
2. Remove Server debug mode.
Message
: Insufficient Privilege Level The web page is non-accessible. Please use the valid privilege
level.
Meaning
: Issue with privilege level after login with RADIUS using a user configured with level 15.
A configured user is allowed to login if RADIUS is the only login method for HTTP or SSH.
Saving the configuration and rebooting after configuring RADIUS will allow the correct authentication.
Only RADIUS authenticated users can login after reboot.
Recovery
:
1. Save and reboot after adding a RADIUS configuration change.
2. Remove RADIUS Server debug mode.