![Transition Networks S4224 Web User Manual Download Page 238](http://html1.mh-extra.com/html/transition-networks/s4224/s4224_web-user-manual_1152119238.webp)
Transition Networks
S4224 Web User Guide
33558 Rev. C
Page 238 of 669
Delay Measurement
Bins
A Measurement Bin is a counter that stores the number of delay measurements falling within a specified
range, during a Measurement Interval.
Measurement Bins for FD
Configures the number of Frame Delay Measurement Bins per Measurement Interval.
The minimum number of FD Measurement Bins per Measurement Interval supported is
2
.
The maximum number of FD Measurement Bins per Measurement Interval supported is
10
.
The default number of FD Measurement Bins per Measurement Interval supported is
3
.
Measurement Bins for IFDV
Configures the number of Inter-Frame Delay Variation Measurement Bins per Measurement Interval.
The minimum number of FD Measurement Bins per Measurement Interval supported is
2
.
The maximum number of FD Measurement Bins per Measurement Interval supported is
10
.
The default number of FD Measurement Bins per Measurement Interval supported is
2
.
Measurement Threshold
Configures the Measurement Threshold for each Measurement Bin.
The unit for a measurement threshold is in microseconds (
us
).
The default configured measurement threshold for a Measurement Bin is an increment of
5000
us.
Delay Measurement Bins for FD
A Measurement Bin is a counter that stores the number of delay measurements falling within a specified
range, during a Measurement Interval. The FD is the Frame Delay per MEF 10.2.
If the measurement threshold is 5000 us and the total number of Measurement Bins is four, we can give
an example as follows.
Bin
Threshold
Range
bin0
0 us
0 us ≤ measurement < 5,000 us
bin1
5,000 us
5,000 us ≤ measurement < 10,000 us
bin2
10,000 us
10,000 us ≤ measurement < 15,000 us
bin3
15,000 us
15,000 us ≤ measurement < infinite us