TRANSPORTATION AND INSTALLATION MANUAL
124
Customer’s side
P24V
P24G
Diode for preventing counter
electromotive voltage
●
●
DC relay
[Source type (-Common)]
●
b-2) Output signal connector HAND (TSL3100
Type-P)
Pin
Signal name
Signal No.
Output circuit and example of connections
B5
D_OUT1
Output signal 1
201
A6
D_OUT2
Output signal 2
202
B6
D_OUT3
Output signal 3
203
A7
D_OUT4
Output signal 4
204
B7
D_OUT5
Output signal 5
205
A8
D_OUT6
Output signal 6
206
B8
D_OUT7
Output signal 7
207
A9
D_OUT8
Output signal 8
208
A10
DC 24V GND (P24G)
B10
DC 24V GND (P24G)
By using the 24 VDC power of the controller, a relay, solenoid valve, etc., can be driven.
To use external power supply, connect GND of the external power supply with the 24
VDC GND (P24G) of the robot controller (GND common connection). However, do
NOT connect the external power 24V with the 24 VDC (P24V) of the robot
controller. Otherwise, the power supply may be damaged.
Output specifications: Rated voltage: 24 VDC
Rated current: 100 mA
• When a relay or solenoid valve, etc., is connected, it is necessary to use a surge killer
or diode to absorb the surge voltage.
• The right figure shows the DC relay circuit when the external power is used.