TRANSPORTATION AND INSTALLATION MANUAL
102
Connecting and Disconnecting Cables
9.1.6.
!
CAUTION
• Before connecting or disconnecting the cables to or from the robot controller,
be sure to turn off the main power (POWER switch) in advance.
• When disconnecting a cable, be sure to pull the connector and not the cord.
Otherwise, you may damage the cable.
a) Circular connector: ACIN, MOTOR
To connect the connector, align the key position, securely insert the connector on
the cable side into the connector on the robot controller body side, and then tighten
by rotating the lock screw on the cable side clockwise. If the connector is loose, it
may cause accidents due to connector contact failure, so be sure to check that the
connector is securely inserted.
To disconnect the connector, rotate the lock screw counterclockwise, in the opposite
direction from connecting, to loosen the connector, and then pull out the connector
on the cable side.
Fig. 9.4 Connecting/disconnecting the circular connector (TS3100)
Connector on the
controller body side
Connector on the
cable side
Loosen
Tighten
Lock screw
Key position