Q9 ASD Installation and Operation Manual
67
Preset Speed 3
Program
Preset Speeds
This parameter assigns an output frequency to binary number 0011 and is
identified as Preset Speed 3. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed (see
for more information on
this parameter).
Direct Access Number — F020
Parameter Type — Numerical
Factory Default — 0.0
Changeable During Run — Yes
Minimum — Lower-Limit (
)
Maximum — Upper-Limit (
Units — Hz
Preset Speed 4
Program
Preset Speeds
This parameter assigns an output frequency to binary number 0100 and is
identified as Preset Speed 4. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed (see
for more information on this
parameter).
Direct Access Number — F021
Parameter Type — Numerical
Factory Default — 0.0
Changeable During Run — Yes
Minimum — Lower-Limit (
)
Maximum — Upper-Limit (
Units — Hz
Preset Speed 5
Program
Preset Speeds
This parameter assigns an output frequency to binary number 0101 and is
identified as Preset Speed 5. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed (see
for more information on
this parameter).
Direct Access Number — F022
Parameter Type — Numerical
Factory Default — 0.0
Changeable During Run — Yes
Minimum — Lower-Limit (
)
Maximum — Upper-Limit (
Units — Hz
Preset Speed 6
Program
Preset Speeds
This parameter assigns an output frequency to binary number 0110 and is
identified as Preset Speed 6. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed (see
for more information on
this parameter).
Direct Access Number — F023
Parameter Type — Numerical
Factory Default — 0.0
Changeable During Run — Yes
Minimum — Lower-Limit (
)
Maximum — Upper-Limit (
Units — Hz
Preset Speed 7
Program
Preset Speeds
This parameter assigns an output frequency to binary number 0111 and is
identified as Preset Speed 7. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed (see
for more information on
this parameter).
Direct Access Number — F024
Parameter Type — Numerical
Factory Default — 0.0
Changeable During Run — Yes
Minimum — Lower-Limit (
)
Maximum — Upper-Limit (
Units — Hz