User Unit Type
Program
Utility Group
This parameter is used in conjunction with
to set the method in which the
frequency is displayed on the front panel.
will be applied to the display of all frequencies if
All Frequencies are selected at this parameter.
will be applied to parameters
,
ONLY if PID Process Data is selected at this parameter.
Settings:
0 — All Frequencies
1 — PID Process Data
Direct Access Number — F703
Parameter Type — Selection List
Factory Default — All Frequencies
Changeable During Run — Yes
Display Bias
No Path — Direct Access Only
In conjunction with the setting of
, this parameter sets the bias of the front
panel speed display.
The frequency entered here will be multiplied by the setting of
and then
displayed as the zero value on the front panel display.
Direct Access Number — F706
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — Max. Freq. (
Units — Hz
Change Step Selection 1
No Path — Direct Access Only
In conjunction with the parameter setting of
, this parameter sets the amount
that the output speed will increase or decrease for each speed command change
entered from the front panel using the Rotary Encoder.
Direct Access Number — F707
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — Max. Freq. (
Units — Hz
Change Step Selection 2
No Path — Direct Access Only
The parameter is used to modify the degree that the setting of
affects the
output speed changes that are input from the front panel using the Rotary
Encoder.
Selecting a zero value here disables this parameter and the resulting non-zero
value of parameter setting
is output from the ASD.
Selecting a non-zero value here provides a dividend that will be used in the
following equation resulting in the actual output frequency applied to the motor.
Direct Access Number — F708
Parameter Type — Numerical
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Minimum — 0
Maximum — 255
O utpu tFr equ enc yD is play ed
In te rna lly C omm and edFr eque ncy
F708
F707
-------------
×
=