*
For additional assistance, please contact Toshiba Adjustable Speed Drive Marketing Dept. at (800) 872-
2192
26
12
Adjustable Remote Torque Limit
Introduction
The following programming steps enable on-the-fly remote torque limit on the G3. This limit is
adjusted via a speed pot connected to the ‘RR’ terminal. If you want to use another speed pot for a
speed reference, connect its wiper to ‘RX’ and do the required programming (not listed here). After
this programming is completed, a new group, GROUP:SUPERUSER, will be visible. Cycle drive
power after programming.
Connections
TERMINAL STRIP
ST CC
PP RR CC
Programming
Group
Parameter
Value
UTILITY PARAMETERS
Blind Function Selection
1
UTILITY PARAMETERS
Feedback Control Parameters Blind
1
UTILITY PARAMETERS
Protection Function Parameters Blind
1
UTILITY PARAMETERS
Terminal Selection Parameters Blind
1
FUNDAMENTAL PARAMETERS #1
Volts per Hertz Pattern
5
FEEDBACK PARAMETERS
Drooping Control Enable
1
FEEDBACK PARAMETERS
Drooping Control Amount
5
PROTECTION PARAMETERS
Stall Protection Enable
1
TERMINAL SELECTION PARAMETERS RR Input Special Function Select
4
See Guideline 18, True Torque Control for motor tuning information (necessary for torque
regulation).