Example of fixed 100% output calibration of the FM terminal for reference frequency
¾
Adjust Jumper 4 for 0-1 or 4-20 mA output
¾
Connect meter to ‘FM’ and ‘CC’
.
¾
Programming
Group
Parameter
New Value
UTILITY PARAMETERS
Blind Function Selection
1
UTILITY PARAMETERS
AM/FM Adjustment Parameters Unblind
1
AM/FM TERMINAL ADJUSTMENT PARAMETERS
FM Terminal Function Selection
14
AM/FM TERMINAL ADJUSTMENT PARAMETERS
Frequency Meter Adjustment
*
AM/FM TERMINAL ADJUSTMENT PARAMETERS
FM Terminal Function Selection
2
* the drive shows ‘100%’. Use the up/down arrows to make meter read the same as the value found in the
“Calibration Reading” column on page 2. The drive’s display will not change. Hit ENTER when
adjusted.
Example of fixed 100% output calibration of the AM terminal for output current
¾
Adjust jumper 4 for 0-1 or 4-20 mA output
¾
Connect meter to ‘AM’ and ‘CC’.
¾
Programming
Group
Parameter
New Value
UTILITY PARAMETERS
Blind Function Selection
1
UTILITY PARAMETERS
AM/FM Adjustment Parameters Unblind
1
AM/FM TERMINAL ADJUSTMENT PARAMETERS
AM Terminal Function Selection
14
AM/FM TERMINAL ADJUSTMENT PARAMETERS
Current Meter Adjustment
**
AM/FM TERMINAL ADJUSTMENT PARAMETERS
AM Terminal Function Selection
3
** adjust until meter reads rated drive amps (or 100% if meter reads percent). Hit ENTER when adjusted.
Example of fixed 100% output calibration of the FM terminal for DC bus voltage
¾
Adjust jumper 4 for 0-1 or 4-20 mA output
¾
Connect meter to ‘FM’ and ‘CC’
.
¾
Programming
Group
Parameter
New Value
UTILITY PARAMETERS
Blind Function Selection
1
UTILITY PARAMETERS
AM/FM Adjustment Parameters Unblind
1
AM/FM TERMINAL ADJUSTMENT PARAMETERS
FM Terminal Function Selection
14
AM/FM TERMINAL ADJUSTMENT PARAMETERS
Frequency Meter Adjustment
***
AM/FM TERMINAL ADJUSTMENT PARAMETERS
FM Terminal Function Selection
4