- 48 -
6.2.4
Self-test Printout Contents
(1) Maintenance
counter
Item Contents
Range
TOTAL FEED
Total label distance covered
(cannot be cleared)
0.0 to 3200.0 km
FEED
Label distance covered
0.0 to 3200.0 km
Print distance
0.0 to 200.0 km
CUT
Cut count
0 to 1000000
HEAD U/D
Head up/down count
0 to 2000000
RIBBON
Ribbon motor drive time
0 to 2000 hours
SOLENOID
Head-up solenoid drive time
0 to 1000 hours
232C ERR
RS-232C hardware error count
0 to 255
SYSTEM ERR
System error count
0 to 15
POWER FAIL
Momentary power interruption count
0 to 15
RFID WT OK
TAGS
Number of successful RFID write
0 to 9999999
RFID VOID
PRINT TAGS
Number of failure in RFID write
0 to 9999999
Maintenance Counter
Count Conditions
Total label distance covered
Label distance covered
Counts when the paper feed motor is driven to feed a
paper or print. (Counts also during a reverse feed
operation.)
When the power is off, the label distance of 50.0 cm or less
may be rounded down and backed up.
Print distance
Counts while printing. (Counting is not performed during
reverse feed operation.)
B-SX4:
When the power is off, the print distance of 8.2 m or less
is rounded down and backed up.
B-SX5:
When the power is off, the print distance of 5.5 m or less
is rounded down and backed up.
Cut count
Every cut operation is counted.
When the power is off, a cut count of 31 or less is rounded
down and backed up.
Head up/down count
Counts head up/down operations using the ribbon saving
solenoid. (Combination of up and down operations is
counted as one.)
When the power is off, an up/down count of 31 or less is
rounded down and backed up.
Ribbon motor drive time
Counts when the ribbon motor is driven to feed a paper or
print. (Counts also during a reverse feed operation.)
For B-SX4:
When the power is off, a drive time of 32 seconds or less is
rounded down and backed up.
For B-SX5:
When the power is off, a drive time of 27 seconds or less is
rounded down and backed up.