![Toshiba B-SX4 Series Key Operations Manual Download Page 104](http://html.mh-extra.com/html/toshiba/b-sx4-series/b-sx4-series_key-operations-manual_424358104.webp)
- 101 -
6.6.2 Display
Contents
(1) Sensor adjustment value display
[ H ] 2 0 ° C [ A ] 2 2 ° C
[ S ] 2 5 ° C
[ R E F L E C T ]
3 . 8 V
[ T R A N S . ]
2 . 3 V
[ P E ] R 0 . 2 V
T 4 . 6 V
[ R I B B O N ]
4 . 1 V
(2) Supplementary explanation
• During the sensor check, each sensor status is monitored and displayed every 200 msec.
(When the sensor status is changed, the display also changes.)
• When the [FEED] and [RESTART] keys are entered at the same time, the system mode
menu is displayed.
Open-air temperature sensor status
(0 °C to 86 °C)
Thermal head temperature sensor status
(0 °C to 86 °C)
Heat sink sensor status
(25 °C, 80 °C, 90 °C, 99 °C)
*: When the Part No. of the MAIN PC Board is 7FM00503x00, this value
is not displayed.
Reflective sensor status without paper
(0.0 V to 5.0 V)
Transmissive sensor status without paper
(0.0 V to 5.0 V)
Reflective sensor status
(0.0 V to 5.0 V)
Transmissive sensor status
(0.0 V to 5.0 V)
Ribbon end sensor status
(0.0 V to 5.0 V)