- 37 -
6. SYSTEM MODE
6.1 OUTLINE OF SYSTEM MODE
In this mode, the printer self-test operation and parameter setting operation are performed.
Described below is the key operation procedure performed regarding the system mode.
z
System mode for service persons and system administrators (All system mode menus are
available.)
While holding the [FEED] and [PAUSE] keys down, turn the power on.
Maintenance counter/Various parameters printout,
Printer self-test operation and results printout,
Thermal head broken dots check
Character code selection, Font “0” selection, Communication speed
selection, Data length selection, Stop bit length selection, Parity selection,
Transmission control method selection, Language selection for LCD
messages, Setting for forward feed standby, Forward feed standby action,
Setting for head-up operation in cut issue mode or for using the rewinder,
Installed solenoid type setting, Ribbon saving system setting, Control code
selection, Peel-off wait status selection, [FEED] key function setting, Kanji
code selection, Euro code setting, Automatic head broken dots check setting,
Centronics ACK/BUSY timing setting, Web printer function setting, Ribbon
near end detection setting
Reset process when the nInit signal is ON, Expansion I/O operation mode
setting, Centronics operation mode setting, Plug-and-Play operation setting,
Label end/ribbon end process setting, Pre-peel-off process setting, Back feed
speed setting, MaxiCode specification setting, Print head type setting,
System mode password operation setting, XML function setting (V4.4A only)
Feed fine adjustment, Cut position fine adjustment (or strip position
fine adjustment), Back feed fine adjustment,
X-coordinate fine adjustment, Print density fine adjustment (Thermal
transfer/Direct thermal print mode), Ribbon motor drive voltage fine
adjustment, Transmissive sensor manual threshold fine adjustment,
Reflective sensor manual threshold fine adjustment,
Power OFF
[RESTART]
[FEED]
[RESTART]
[FEED]
[RESTART]
[FEED]
[RESTART]
[FEED]
[RESTART]
Parameter setting, 1-dot slant line printout, 3-dot slant line printout,
Character printout, Bar code printout, Non-printing
Automatic printout for the assembly process (Transmissive
sensor/Reflective sensor), Factory pattern printout
Thermal head temperature sensor display, Open-air temperature
sensor display, Reflective sensor display/adjustment,
Transmissive sensor display/adjustments,
Sensor status without paper,
Ribbon end sensor status
<1>DIAG.
<2>PARAMETER SET
<3>ADJUST SET
Maintenance counter clear, Various parameters clear
<4>TEST PRINT
<5>SENSOR ADJ.
<6>RAM CLEAR
<7>IP ADDRESS
Printer IP address setting, Gateway IP address setting,
Subnet mask setting, Socket communication port number setting,
DHCP setting, DHCP client ID setting
Head-up adjustment for the process, Option check for the process
[FEED]
[RESTART]
<8>BASIC
[FEED]
[RESTART]
<9>FOR FACTORY
[FEED]
[RESTART]
[FEED]
[RESTART]
BASIC setting, BASIC file browser, BASIC trace setting
Continued on the following page.