5.11 AUTOMATIC CALIBRATION SETTING (SUPPORTED FROM V4.4)
5.11.1 Operation Example of Automatic Calibration Setting
Power ON
O
N L
I
N
E
(1) Idling or printing normally
B - S X 4 T V 4 . 4
[PAUSE]
(2) Press the [PAUSE] key.
P
A
U
S
E
(3) “PAUSE” is displayed.
B - S X 4 T V 4 . 4
[RESTART]
(4) Hold down the [RESTART] key for 3 seconds
or more while the printer is in a pause state.
< 1 > R E S E T
(5) The reset menu is displayed.
[FEED]
(6) Press the [FEED] key.
< 2 > P A R A M E T E R S E T
(7) System mode menu display
(Parameter setting)
[FEED]
(8) Press the [FEED] key.
< 3 > A D J U S T S E T
(9) System mode menu display
(Fine adjustment value setting)
[FEED]
(10) Press the [FEED] key.
< 4 > D U M P M O D E
(11) The receive buffer dumping menu is displayed.
[FEED]
(12) Press the [FEED] key.
< 5 > E X P A N D M O D E
(13) The BASIC expansion mode menu is
displayed.
[FEED]
(14) Press the [FEED] key.
< 6 > A U T O C A L I B
(15) The automatic calibration menu is displayed.
[PAUSE]
(16) Press the [PAUSE] key.