- 54 -
Item Contents
Remarks
RFID MODULE
RFID module type selection
NONE: No RFID kit is installed.
U1: B-9704-RFID-U1-EU/US
H1: B-9704-RFID-H1-QM
H2: B-SX704-RFID-H2
U2: B-SX704-RFID-U2
RFID TAG TYPE
RFID tag type selection
I-Code:
11
Tag-it: 12
C220: 13
ISO15693: 14
C210: 15
C240: 16
C320: 17
EPC Class0:
21
EPC Class1:
22
ISO18000-6B: 23
EPC C1 Gen2: 24
RFID ERR CHECK
RFID error tag detection
ON: Detection is enabled.
OFF: Detection is disabled.
RFID RETRY
Max. number of RFID issue retries
0 to 255
RFID RD CYCLE
Max. number of RFID read retries
RFID read retry time-out
0 to 255
0 to 9.9 sec.
RFID WT CYCLE
Max. number of RFID write retries
RFID write retry time-out
0 to 255
0 to 9.9 sec.
RFID ADJ RETRY
RFID adjustment for retry
-99 mm to +99 mm
RFID POWER LEVEL
RFID wireless power level setting
0 to 255 (for the B-9704-RFID-U1-
US/EU)
18 to 26 (for the B-SX704-RFID-
U2)
RFID THRESHOLD
RFID AGC threshold setting
0 to 15
RFID RF CHANNEL
RFID channel setting
2CH to 8CH
AUTO
XML SPEC
(Supported only
by V4.4A)
XML function setting
STD: Standard specification
ORACLE: Specification for Oracle
NOTE: For the B-SX4, the head density is 8 dots/mm. If the value is set to “x.2 mm” or “x.3
mm”, the operation to be performed is the same for both. Therefore, “x.3 mm” is
printed on the maintenance counter printout, even if “x.2 mm” is set. Similarly, if “x.7
mm” is set, “x.8 mm” is printed on the maintenance counter printout.