![Toshiba B-SX4 Series Key Operations Manual Download Page 18](http://html.mh-extra.com/html/toshiba/b-sx4-series/b-sx4-series_key-operations-manual_424358018.webp)
- 15 -
(13) Ribbon saving system setting (RBN SAVE)
• ON (TAG) (The ribbon saving system is used.: When the head lever position is “TAG”.)
• ON (LBL) (The ribbon saving system is used.: When the head lever position is “LABEL”.)
• OFF (The ribbon saving system is not used.)
(14) Control code selection (CODE)
• Automatic selection (ESC, LF, NUL/{ | })
• Manual selection (ESC, LF, NUL method)
• Manual selection ({ | } method)
• Any set code
(15) Peel-off wait status selection (PEEL OFF STS)
• OFF (No peel-off wait status selection)
• ON (Peel-off wait status selection)
(16) [FEED] key function setting (FEED KEY)
• FEED:
One label is fed.
• PRINT: Data in the image buffer is printed on one label.
(17) Kanji code selection (KANJI CODE)
•
TYPE1
•
TYPE2
(18) Euro code setting (EURO CODE)
20H to FFH
(19) Automatic head broken dots check setting (AUTO HD CHK)
• ON: Head broken dots check is automatically performed when the power is turned on.
• OFF: Head broken dots check is not automatically performed if the power is turned on.
(20) Centronics ACK/BUSY timing setting (ACK/BUSY)
• TYPE1 The ACK signal is sent to match the rising edge of ACK signal and the falling
edge of the BUSY signal.
• TYPE2 The ACK signal is sent to match the falling edge of ACK signal and the falling
edge of the BUSY signal.
(21) Web printer function setting (WEB PRINTER)
• ON:
Web printer function is enabled.
• OFF:
Web printer function is disabled.
(22) Reset process when the nInit signal is ON (INPUT PRIME)
• ON: Reset process is performed.
• OFF: Reset process is not performed.
(23) Ribbon near end detection setting (RBN NEAR END)
• OFF: The ribbon near end state is not detected.
• 30 m: The ribbon near end state is when the remaining ribbon length is 30 m.
• 70 m: The ribbon near end state is when the remaining ribbon length is 70 m.
(24) Expansion I/O operation mode setting (EX. I/O)
•
TYPE1:
Standard
mode
•
TYPE2:
In-line
mode
(25) Centronics operation mode setting (CENTRO. MODE)
•
SPP:
Compatibility
mode
•
ECP:
ECP
mode