Handling and Control
7-2
Heratherm IMP
Thermo Scientific
The table below contains brief descriptions of the display features of the control panel (items
D1 through D6 in
; the identifiers K1
through K4
refer to the buttons shown in
that figure).
Table 7-1 Control Buttons
Icon
Item
Function
K1
Menu/Enter
button
First key press:
Activates the menu, highlighting the first menu
item with a red border (see D3).
Second key press:
Selects the currently activated menu item
(as highlighted by the red border). Depending on the currently
selected function, pressing this button enables entries with item
D2, D5 or D6.
Third key press (once a setting has been changed):
Confirms
a previous entry or selection.
K2
Left button
After the first press of the Menu/Enter button:
- Moves the selection in the menu (see item D3) to the next icon
on the left.
Once a menu item has been selected:
- Decreases an adjustable parameter value - for example, the
temperature set value in D5 or the fan speed level at D6.
Hold
-
ing this button depressed for a few seconds changes the
selected value in quick run mode.
- Moves the selection in the multifunctional display pane in D2 in
the currently activated menu item to the next option on the left -
for example, from the
Off
state of the timer to
On
.
K3
On/Off Button
Holding this button depressed for 2 seconds switches the refrig
-
erated incubator off. The display window goes out, except for the
readiness indicator icon in the status display area at item D4.
The temperature display field D1 provides a dimmed readout of
the work space temperature, provided that the temperature
exceeds 50
°C (122
°F).
K4
Right button
After the first press of Menu/Enter button:
- Moves the selection in the menu (see item D3) to the next icon
on the right.
Once a menu item has been selected:
- Increases an adjustable parameter value - for example, the
temperature set value in D5 or the fan speed level at D6. Hold
-
ing this button depressed for a few seconds changes the
selected value in quick run mode.
- Moves the selection in the multifunctional display pane in D2 in
the currently activated menu item to the next option on the left -
for example, from the Off state of the timer to On.
K5
Escape
button
Returns to the previous level of the menu or standard display.
Upon exiting from the current menu item the user may be
prompted to save any previously made settings.
Summary of Contents for IMP 180
Page 1: ......
Page 6: ...Contents iv Heratherm IMP Thermo Scientific...
Page 8: ...List of Figures ii Heratherm IMP Thermo Scientific...
Page 40: ...Product Description Additional Tube Access Ports Option 4 14 Heratherm IMP Thermo Scientific...
Page 88: ...Handling and Control Programming 7 34 Heratherm IMP Thermo Scientific...
Page 90: ...Shut down Shutting the refrigerated incubator down 8 2 Heratherm IMP Thermo Scientific...
Page 110: ...Technical Data 13 4 Heratherm IMP Thermo Scientific...
Page 114: ...Device Log 15 2 Heratherm IMP Thermo Scientific...
Page 117: ...Contact Thermo Scientific Heratherm IMP 16 3...
Page 118: ...Contact 16 4 Heratherm IMP Thermo Scientific...