Maintenance Inspection Schedule
4-4
UNIT MODELS: ALL SL, SLe AND SPECTRUM MODELS HOST UNIT
The service technician is responsible for assessing the condition of
all parts & components found during any service operation to be
in a condition suitable for further operation up to the next
scheduled service. If parts not considered in suitable condition
they should be replaced.
Check/Inspect/Adjust/Change/Replace
INSPECTION
A SERVICE
Every 1000 hours
Or every 6
Months
(whichever comes
first)
B SERVICE
Every 3000
hours
Or every 24
Months
(whichever
comes first)
SERVICE
C SERVICE
Every 4500 hours
Or every 48
Months
(whichever comes
first)
EDAC Labour standard
1.5 hr
2.5 hrs
7.5 hrs
For SPECTRUM
8.0 hrs
Structural & Trailer Body
Check all doors: operation & hardware security
Visually inspect unit for damaged, loose or broken skins, parts &
fittings (includes air ducts and bulkheads)
Check all unit mounting bolts, external mounted equipment &
wiring, hoses, fuel lines etc.
Clean copper tube and fin condenser
Clean evaporator coil and defrost drains of debris.
Miscellaneous
Check accuracy of return and discharge sensors as per local
regulations
Check operation of all unit attached accessories Thermo King and
non Thermo King.
Check service records and ensure all service and warranty
modifications have been completed. Upgrades not included.
*Do not mix antifreeze types.
** Wet cell battery may need to be topped up more regularly where unit is operating in high ambients for longer periods. Refer
to Service Bulletin Silver Calcium Batteries
*** EON battery is maintenance free and does not require topping up of electrolyte.
**** If no drain plug is available in the fuel tank the tank manufacturer should provide clear instructions for fuel cleaning. For
fuel supplies taken from the truck tank the truck manufacturer's instructions should be adhered to.
***** The injector service may be required more frequently depending on the type and specification of diesel fuel used.
Refer to the latest service bulletins for additional information.
Summary of Contents for SLXi Spectrum
Page 17: ...Safety Precautions 2 5 Warning Decals...
Page 18: ...Safety Precautions 2 6 Warning Decals Information Decals...
Page 74: ...Unit Description 5 30...
Page 128: ...Controller Operation 7 28...
Page 156: ...Electrical Maintenance 8 28...
Page 234: ...Refrigeration Maintenance 10 22...
Page 309: ...13 Mechanical Diagnosis TK 482 TK 486 and TK 486V Engines 13 2...
Page 316: ...Mechanical Diagnosis 13 8...
Page 322: ...Refrigeration System Diagnosis 14 6...
Page 332: ...Single Temperature Refrigeration System Diagrams 15 10...
Page 339: ...Multi Temperature Refrigeration System Diagrams 16 7...
Page 340: ...Multi Temperature Refrigeration System Diagrams 16 8...