Structural Maintenance
12-30
Assembly
The fan shaft is symmetrical and either end can be put into the unit first. However, the fan shaft must be installed from the control
box side of the unit.
1. Install the compressor side bearing assembly (item 6) and fasten it securely. The compressor side bearing is self-aligning and
does not need to be adjusted.
2. Bolt the seal plates (item 10) loosely in place. Make sure to spray dry film lubricant (item 22) on the outer surfaces of the seal
plates (the sides with “THIS FACE UP” stamped on them are the surfaces that contact the rubber seals).
Install Fan Shaft from Control Box Side – SL and SLe
1.
Seal Plate (item 10)
2.
Fan shaft (item 5) is symmetrical. Insert either end first
Install Control Box Side Condenser Blower and
Orifice – SL and SLe
1.
Control Box Side Condenser Blower (item 4)
2.
Control Box Side Condenser Orifice (item 2)