TK 482, TK 486 and TK 486V Engines
NOTE: This diagnosis guide applies to units equipped with TK 482, TK 486 and TK 486V engines.
For major repair of TK 482, TK 486 and TK 486V engines, refer to Overhaul Manual TK 50136.
NOTE: For diagnosis of units, see the appropriate Controller Operation and Diagnosis manual.
CONDITION
POSSIBLE CAUSE
REMEDY
Unit switch OFF; LCD blank
(
μ
P-VI controller)
NOTE: A blank LCD is normal on
units with Screen Blanker.
Batteries discharged
Charge or replace batteries
Corroded battery cable connections Clean and tighten
Fuse link blown
Check for short circuit and replace fuse link
Fuse F12 blown (F10 on DE, TC,
TCI and SPECTRUM models)
Check for short circuit and replace fuse
Microprocessor switch turned OFF Check switch
Open circuit
Check 2, 2P and 2PA circuits
Unit switch ON; LCD backlight
does not come on (TG-VI,
μ
P-IV,
μ
P-V or
μ
P-VI controller)
Fuse F9 blown (F20 on DE, TC,
TCI and SPECTRUM models)
Check for short circuit and replace fuse
Faulty On/Off switch
Check switch
Fuse F21 blown (F22 on DE, TC,
TCI and SPECTRUM models)
Check for short circuit and replace fuse
Emergency switch not in µP-IV
position
Check switch
Open circuit
Check 2A, 2AA, 2AB, 8 and 8F circuits
Summary of Contents for SLXi Spectrum
Page 17: ...Safety Precautions 2 5 Warning Decals...
Page 18: ...Safety Precautions 2 6 Warning Decals Information Decals...
Page 74: ...Unit Description 5 30...
Page 128: ...Controller Operation 7 28...
Page 156: ...Electrical Maintenance 8 28...
Page 234: ...Refrigeration Maintenance 10 22...
Page 309: ...13 Mechanical Diagnosis TK 482 TK 486 and TK 486V Engines 13 2...
Page 316: ...Mechanical Diagnosis 13 8...
Page 322: ...Refrigeration System Diagnosis 14 6...
Page 332: ...Single Temperature Refrigeration System Diagrams 15 10...
Page 339: ...Multi Temperature Refrigeration System Diagrams 16 7...
Page 340: ...Multi Temperature Refrigeration System Diagrams 16 8...