Refrigeration Service Operations
11-20
2. Lubricate the O-rings with refrigeration oil. Place one on the stepper motor and piston assembly and place the other in the
valve body.
Install O-Ring on Stepper Motor and Piston Assembly
Install O-Ring Valve Body
3. Place stepper motor and piston assembly into the valve body and make sure the arrowhead marks on them are aligned as
shown below (picture applicable for ETV standard from October 2016 only).
Align Arrowhead Marks
4. For latest version ETV released in October 2016 - Install the four screws and torque them to 4.4 ± 0.4 ft-lb (6.0 ± 0.5 N•m).
For previous reversion ETV(s) - Screw the nut that attaches the stepper motor and piston assembly to the valve body.
5. Connect the main/unified wire harness to the ETV at the four-pin connector/ETV harness wire connector.
6. Pressurize the low side and test for leaks.
7. If no leaks are found, evacuate the low side.
8. Open the refrigeration valves and place the unit in operation.
ARA2502
ARA2503
ARA2504
Summary of Contents for SLXi Spectrum
Page 17: ...Safety Precautions 2 5 Warning Decals...
Page 18: ...Safety Precautions 2 6 Warning Decals Information Decals...
Page 74: ...Unit Description 5 30...
Page 128: ...Controller Operation 7 28...
Page 156: ...Electrical Maintenance 8 28...
Page 234: ...Refrigeration Maintenance 10 22...
Page 309: ...13 Mechanical Diagnosis TK 482 TK 486 and TK 486V Engines 13 2...
Page 316: ...Mechanical Diagnosis 13 8...
Page 322: ...Refrigeration System Diagnosis 14 6...
Page 332: ...Single Temperature Refrigeration System Diagrams 15 10...
Page 339: ...Multi Temperature Refrigeration System Diagrams 16 7...
Page 340: ...Multi Temperature Refrigeration System Diagrams 16 8...