Electrical Maintenance
8-9
Rotor
1. Place 15 volts dc across the slip rings on the rotor.
CAUTION: Turn off the dc power source before installing or removing test leads on slip rings to prevent arcing and damage
to the slip ring surface.
2. Check the current draw. The draw should be near the appropriate value shown in the following chart.
3. Remove the power source from the rotor.
4. Check resistance. Resistance of winding should be near specified resistance.
5. Check for grounded slip ring or windings by placing an ohmmeter across the rotor body and the slip rings.
Should be no continuity.
6. Check condition of slip rings.
a. Clean the brush contacting surfaces with a fine crocus cloth, wipe dust and residue away.
b.If surfaces are worn beyond this restoration, replace the entire rotor assembly.
7. Replace entire rotor assembly if any of the following conditions exist:
a. Stripped threads on shaft.
b.Worn bearing surfaces.
c. Scuffed pole fingers.
Rear Housing Inspection
1.
O-ring
2.
Bearing Bore
Alternator
Current Draw
23 amp
37 amp
65 amp
120 amp
2.5 amps @ 20.0°C
5.18 amps @ 25.0°C
5.77 amps @ 25.0°C
Not Available
Alternator
Rotor Resistance
23 amp
37 amp
65 amp
120 amp
6.0 Ohms @ 20.0°C
2.9 Ohms @ 25.0°C
2.6 Ohms @ 25.0°C
2.6 Ohms @ 25.0°C
Summary of Contents for SLXi Spectrum
Page 17: ...Safety Precautions 2 5 Warning Decals...
Page 18: ...Safety Precautions 2 6 Warning Decals Information Decals...
Page 74: ...Unit Description 5 30...
Page 128: ...Controller Operation 7 28...
Page 156: ...Electrical Maintenance 8 28...
Page 234: ...Refrigeration Maintenance 10 22...
Page 309: ...13 Mechanical Diagnosis TK 482 TK 486 and TK 486V Engines 13 2...
Page 316: ...Mechanical Diagnosis 13 8...
Page 322: ...Refrigeration System Diagnosis 14 6...
Page 332: ...Single Temperature Refrigeration System Diagrams 15 10...
Page 339: ...Multi Temperature Refrigeration System Diagrams 16 7...
Page 340: ...Multi Temperature Refrigeration System Diagrams 16 8...