Structural Maintenance
12-6
SL and SLe Top Center Nut
To reach the top center nut when installing unit:
1. Open the control box side condenser grille door.
2. Remove the coil blower access panel. This is the diagonal panel just above the blower inlet area.
3. Install the mounting bolt washer and nut. Tighten using wrench socket and swivel attachment.
4. Replace the access panel. The unit will not operate properly with the panel removed.
NOTE to trailer manufacturer: Not all trailer configurations will permit adding the top center unit mounting bracket assembly
9154C10G01. The top center mounting bolt can be permanently mounted to the trailer structure as part of the trailer. Trailer
structure to support mounting bolt must fit within the limits of the evaporator assembly bolt pocket to avoid interference with
the unit during installation.
SL and SLe Top Center Mounting Bolt Installation
A.
Side View
B.
Front View
1.
Unit Condenser Coil
2.
Trailer Ceiling
3.
Unit Foam
4.
Evaporator Bolt Pocket
5.
Mounting bolt assembly supplied with unit installation kit
Summary of Contents for SLXi Spectrum
Page 17: ...Safety Precautions 2 5 Warning Decals...
Page 18: ...Safety Precautions 2 6 Warning Decals Information Decals...
Page 74: ...Unit Description 5 30...
Page 128: ...Controller Operation 7 28...
Page 156: ...Electrical Maintenance 8 28...
Page 234: ...Refrigeration Maintenance 10 22...
Page 309: ...13 Mechanical Diagnosis TK 482 TK 486 and TK 486V Engines 13 2...
Page 316: ...Mechanical Diagnosis 13 8...
Page 322: ...Refrigeration System Diagnosis 14 6...
Page 332: ...Single Temperature Refrigeration System Diagrams 15 10...
Page 339: ...Multi Temperature Refrigeration System Diagrams 16 7...
Page 340: ...Multi Temperature Refrigeration System Diagrams 16 8...