Multi-Temperature Refrigeration System Diagrams
16-6
SLX, SLXe, SLXi SPECTRUM
Zone 1* on Cool, Zone 2** on Heat
Note: SLX Spectrum ETV and SLXe/SLXi Spectrum modes are the same as the SLX Spectrum with the exception of host
only operation, then Modulation control is activated for host zone.
Note: Early generation of SLX Spectrum units (until 04-2012) are fitted with MTV (not ETV). Therefore, please refer to
pages 15-2 and 15-3 for these Host unit diagrams
Z-1 Zone 1 Evaporator* (Host Unit): COOL
1.
Liquid Line Solenoid (LLS) – Open
2.
Liquid Return Check Valve (LRCV) – Closed
3.
Suction Line Check Valve (SLCV) – Open
4.
Suction Line Solenoid (SLS) – Open
5.
Hot Gas Solenoid (HGS) – Closed
6.
Condenser Inlet Solenoid (CIS) – Closed****
7.
Condenser Inlet Check Valve (CICV) – Closed
8.
Receiver Tank Pressure Solenoid (RTPS) –
Open****
9.
Condenser Check Valve (CCV) – Closed
10. Bypass Hand Valve
11. Purge Valve (PV) – Open****
12. Purge Check Valve (PCV) – Open
13. Hot GAs Bypass solenoid (HGBS)
14. Electronic Throttling Valve
Z-2 Zone 2 Evaporator**: HEAT
1C. Zone 2 Liquid Line Solenoid (LLS2) – Open
2C. Zone 2 Liquid Return Check Valve (LRCV2) –
Closed
3C. Zone 2 Suction Line Check Valve (SLCV2) –
Open
4C. Zone 2 Suction Line Solenoid (SLS2) – Open
5C. Zone 2 Hot Gas Solenoid (HGS2) – Closed
Summary of Contents for SLXi Spectrum
Page 17: ...Safety Precautions 2 5 Warning Decals...
Page 18: ...Safety Precautions 2 6 Warning Decals Information Decals...
Page 74: ...Unit Description 5 30...
Page 128: ...Controller Operation 7 28...
Page 156: ...Electrical Maintenance 8 28...
Page 234: ...Refrigeration Maintenance 10 22...
Page 309: ...13 Mechanical Diagnosis TK 482 TK 486 and TK 486V Engines 13 2...
Page 316: ...Mechanical Diagnosis 13 8...
Page 322: ...Refrigeration System Diagnosis 14 6...
Page 332: ...Single Temperature Refrigeration System Diagrams 15 10...
Page 339: ...Multi Temperature Refrigeration System Diagrams 16 7...
Page 340: ...Multi Temperature Refrigeration System Diagrams 16 8...