Unit Description
5-14
Engine Operation
Continuous Mode for
µP-VI (with ETV
)
• High Speed Cool
• Low Speed Cool
• Low Speed Modulated Cool
1
• Low Speed Modulated Heat
1
• Low Speed Heat
• High Speed Heat
1
• Defrost
1
ETV operation and High Speed Heat are locked out if controller setpoint is below Fresh/Frozen temperature setting.
Continuous Mode with SR-2/SR-3
(without ETV
)
• High Speed Cool
• Low Speed Cool
• Low Speed Heat
• High Speed Heat
1
• Defrost
1
High Speed Heat is locked out if controller setpoint is below Fresh/Frozen temperature setting.
Continuous Mode with SR-2/SR-3
(with ETV
)
• High Speed Cool
• Low Speed Cool
• Low Speed Modulated Cool
1
• Low Speed Modulated Heat
1
• High Speed Modulated Cool
1
• High Speed Modulated Heat
1
• Low Speed Heat
• High Speed Heat
1
• Defrost
1
ETV operation and High Speed Heat are locked out if controller setpoint is below Fresh/Frozen temperature setting.
CYCLE-SENTRY Mode
1, 2
• High Speed Cool
3
• Low Speed Cool
3
• Null
4
• Low Speed Heat
5
• High Speed Heat
5
• Defrost
1
ETV operation is locked out during CYCLE-SENTRY operation.
2
If engine temperature, battery condition or defrost initiation requires unit start-up during Null mode, unit starts and operates
in Low Speed Heat or Low Speed Cool.
3
After initial unit start-up and unit pull-down to setpoint, the controller limits Low Speed Cool operation when the controller
setpoint is below Fresh/Frozen temperature setting. On increasing compartment temperature, the unit operates in Low Speed
Cool for a maximum of 8 minutes in an attempt to reach setpoint. If setpoint is not reached within 8 minutes, the unit will
operate in High Speed Cool until setpoint is reached.
4
Unit mode is Null when the engine temperature and battery are satisfied.
5
Null mode if setpoint is below Fresh/Frozen temperature setting.
Summary of Contents for SLXi Spectrum
Page 17: ...Safety Precautions 2 5 Warning Decals...
Page 18: ...Safety Precautions 2 6 Warning Decals Information Decals...
Page 74: ...Unit Description 5 30...
Page 128: ...Controller Operation 7 28...
Page 156: ...Electrical Maintenance 8 28...
Page 234: ...Refrigeration Maintenance 10 22...
Page 309: ...13 Mechanical Diagnosis TK 482 TK 486 and TK 486V Engines 13 2...
Page 316: ...Mechanical Diagnosis 13 8...
Page 322: ...Refrigeration System Diagnosis 14 6...
Page 332: ...Single Temperature Refrigeration System Diagrams 15 10...
Page 339: ...Multi Temperature Refrigeration System Diagrams 16 7...
Page 340: ...Multi Temperature Refrigeration System Diagrams 16 8...