Structural Maintenance
12-42
Lower Blower Assembly SLXi, SLXe, SLX
In these units, the two Condenser Blowers are in different positions to the SL. (Upper and Lower Blowers, instead of left and
right of the Evaporator Blower) The Upper Blower is similar to the SL Blower. Here is the Lower Blower assembly.
Note: See Chapter 9, (9-31) Belt Arrangement SLXi, SLXe, SLX for more details.
Removal
1. Remove the Upper Belt Drive
2. Loosen Orifice Mounting Screws (x3)
3. Remove Front mounting Bracket Bolts (x3) and Screw caps (x2)
4. With the Front mounting Plate removed, remove the remaining Cap screws (x2), holding the blower spindle onto the rear
mounting Bracket.
5. Loosen the Screws (7 below x 4) which hold the bearing Hub into the blower. Ensure that the screws do not come out of the
hub.
6. Allow the bearing and the spindle to slide into the blower.
7.
Remove Blower.
Lower Blower Assembly - SLXi, SLXe, SLX
1.
Blower Fan
2.
Hub Lower
3.
Pulley Lower
4.
Bearing
5.
Spacer
6.
Washer Lock, M8
7.
Screw, M8
8.
Screw, Weight Balancing
9.
Wave washer
10. Spindle
11. Ring Snap
3
2
4
6
7
08
1
5
4
5
6
7
09
10
11
Summary of Contents for SLXi Spectrum
Page 17: ...Safety Precautions 2 5 Warning Decals...
Page 18: ...Safety Precautions 2 6 Warning Decals Information Decals...
Page 74: ...Unit Description 5 30...
Page 128: ...Controller Operation 7 28...
Page 156: ...Electrical Maintenance 8 28...
Page 234: ...Refrigeration Maintenance 10 22...
Page 309: ...13 Mechanical Diagnosis TK 482 TK 486 and TK 486V Engines 13 2...
Page 316: ...Mechanical Diagnosis 13 8...
Page 322: ...Refrigeration System Diagnosis 14 6...
Page 332: ...Single Temperature Refrigeration System Diagrams 15 10...
Page 339: ...Multi Temperature Refrigeration System Diagrams 16 7...
Page 340: ...Multi Temperature Refrigeration System Diagrams 16 8...