Structural Maintenance
12-15
When it stops, the flat should be on the left side of the output shaft and approximately parallel with the vertical sides of the
gear case. In this position the damper would be open. The output shaft must be in this position (damper open) when the damper
motor is being installed in the unit.
NOTE: If the damper motor assembly does not function properly, it should not be installed.
Damper Motor Installation
1. Make sure that the flat is on the left side of the damper motor output shaft (see “Damper Motor Test” earlier in this chapter).
2. Attach the damper motor assembly to the damper motor bracket.
Install Damper Link – SL
1.
Damper Link
2.
Damper Motor Bracket
Ball Joint Link – SL
Center Ball Joint Link to Damper Bracket – SL, SMX
and SMX-II
1.
Damper Bracket
2.
Spacer Washers
3.
Ball Joint Link