Press the EXIT bu
play. Press the STORE button to
tton again to close the Pattern Editor. Changes to a pattern are indicated by a flashing dis-
save the pattern to memory.
Sequencer Track
Track Editor (1-8)
Use this submenu to open the Track Editor for drum sequences. Up to 8 tracks can be programmed, which
can then be triggered within a preset using the hold switch. A track sequence consists of up to 32 steps in
which you can combine patterns in any order or repeat them as needed. Select the desired track number with
the VALUE +/- buttons and press ENTER to start programming the track. Press the EXIT button again to close
the Track Editor.
Step (ST)
(0-31)
Enter the step number of the track
32 steps are available.
sequence here. The individual steps will be played in order. A maximum of
uld be repeated within the step specified in ST.
lues will repeat the pattern the given number of times. The
ut at
Pattern (PT)
(1-32)
ttern to be played back at the step number specified in ST. Changes to a track are indicated by a
flashing display. Press the STORE button to save the track to memory.
Count (C)
(0-99)
Use this parameter to set the number of times the pattern sho
The value 1 will play the pattern once. Higher va
value 0 marks the end of a track sequence. The drum sequencer will automatically cancel the track outp
this point.
Select the pa
ADC Monitor (ADC MON)
This option will provide you with an insight into t
ENTER button to monitor the digitised h
he ANALOG/DIGITAL CONVERTER of your AXON. Press the
ex data generated by the AXON from the analogue string signals. This
ful for diagnostic purposes, when detecting defects in the cable between the guitar interface and
can be use
the AXON, for example.