D-2
Phaser 480 Field Service
D
Test Pattern Generator
To use the Test Pattern Generator, follow this procedure:
1.
Select a test pattern using the Test Pattern Generator's five DIP
switches. Table D-1 lists the available test patterns for the Phaser 480.
2.
Plug the Test Pattern Generator into the printer's parallel port. You do
not have to turn the printer off; you can plug-in the Test Pattern
Generator while the printer is turned on.
3.
Press the Test Pattern Generator's
START
button. Its green LED
flashes as you press the button.
Figure D-1. Plugging the Test Pattern Generator into the printer's parallel port