Service Manual
9-5
Checks and Adjustments
9
Adjusting the +5 VDC output
1.
Turn off the printer.
2.
Remove the top cover and the upper and lower rear covers as detailed
in the Section 8 procedure “The printer covers” on page 8-2.
3.
Remove the engine control board cover which is held in place by two
screws (M3 x 7, panhead).
4.
Connect the positive lead of the voltmeter to pin 1 of J11 (+5V).
Connect the negative lead to pin 4 of J11 (GND).
5.
Close the top cover, plug in the printer’s power cord and turn on the
printer.
6.
Measure the voltage displayed on the voltmeter. Adjust the
potenti5 V to 5 VDC.
7.
After you make the adjustment, remove the voltmeter and turn off the
printer.
8.
Reinstall the covers.
Figure 9-4. Connecting the voltmeter
Ethern
et®
Not Installed
+24V(a)
+5V
8849-37
+5 V adjustment
trimmer
Pin No.1 (+5 V)
V
Pin No 4 (GND)
Connector J11