6.
Examine the crosshairs in the corners of the print for misregistration.
Look for vertical bars of cyan out of alignment (shifted left or right,
short axis of paper) with the yellow bar. The distance cyan is
misaligned to yellow is referred to as X1. The distance cyan is
misaligned to the right of yellow is referred to as X2. If the
misalignment is over 140
µ
, make the appropriate following
adjustment. The vertical yellow bar itself is 85
µ
.
Figure 9-5. Inspecting the test print for misregistration
Figure 9-6. X1 and X2 misregistration
8850-38
100 µ
85 µ
Horizontal
misregistration
140 µ
maximum
Yellow
Green
Cyan
8850-39
Cyan
Cyan
(Left
of the paper)
(Right
of the paper)
Yellow
X
1
X
2