Basic Test Procedures
3–26
CTS850 SDH/PDH Test Set User Manual
1 dB Power Penalty Method.
The 1 dB power penalty method uses the
BER to measure the amount of jitter that is equivalent to a 1 dB loss
of signal power at the optical input of a network element.
1. Connect the CTS850 to the network element as shown in
Figure 3–9.
NE
CTS 850 SDH/PDH Test Set
All Signals are STM-1
Variable
optical
attenuator
Figure 3–9: Setup to Check 1 dB Power Penalty Jitter Tolerance