Setting Jitter/Wander Parameters
CTS850 SDH/PDH Test Set User Manual
3–163
3. The available end frequencies are dependent on the current
transmit rate. To set the end frequency for the jitter generator:
Press Menu
Button
Select Menu
Page
Highlight
Parameter
Select Choice
TEST SETUPS
JITTER TESTS
End Frequency
as appropriate
4. The CTS850 can generate jitter at intermediate frequencies
between the start frequency and end frequency. To set the total
number of frequencies generated (including the start and end
frequencies):
Press Menu
Button
Select Menu
Page
Highlight
Parameter
Select Choice
TEST SETUPS
JITTER TESTS
Number Freq
Samples
as appropriate *
* Number of samples change depending on Start/End frequencies.
5. To set the tolerance criteria:
Press Menu
Button
Select Menu
Page
Highlight
Parameter
Select Choice
Press Menu
Button
Select Menu
Page
Highlight
Parameter
Select Choice
TEST SETUPS
JITTER TESTS
Tolerance Criteria
Onset of Errors
BER Penalty
H
Select Onset of Errors to define the tolerance as two Errored
Seconds in a 30-second time interval.
H
Select BER Penalty to measure the amount of jitter that is
equivalent to a 1 dB loss of signal power at the input of the
network element (optical only).
Summary of Contents for CTS 850
Page 4: ......
Page 24: ...Table of Contents xxiv CTS 850 SDH PDH Test Set User Manual...
Page 33: ...Getting Started...
Page 34: ......
Page 49: ...Operating Basics...
Page 50: ......
Page 105: ...Reference...
Page 106: ......
Page 169: ...Index...
Page 170: ......
Page 178: ...Index Index 8 CTS850 SDH PDH Test Set User Manual...