Setting Jitter/Wander Parameters
CTS850 SDH/PDH Test Set User Manual
3–171
NOTE
. The jitter compliance tests, available through the JITTER
TESTS page of the TEST SETUPS menu, automatically set the jitter
generation parameters needed for the test. When you use the jitter
compliance tests, you do not need to set the controls described below.
Periodic calibration of the jitter generation system is recommended
to maintain best accuracy. You can execute a built–in calibration
routine before making critical measurements. Refer to the Jitter
Calibration information located at the end of the this section.
Turning on Jitter or Wander Generation
To turn on jitter or wander generation:
Press Menu
Button
Select Menu
Page
Highlight
Parameter
Select Choice
TRANSMIT
JITTER &
WANDER
Jitter/Wander
Generation
Off
On
H
Select Off to disable jitter/wander generation.
H
Select On to enable jitter/wander generation.