Basic Test Procedures
CTS850 SDH/PDH Test Set User Manual
3–13
9. Change the downstream CTS850 as follows:
Press Menu
Button
Select Menu
Page
Highlight
Parameter
Select Choice
Results
Main Results
SDH Defects
none
10. Press the START/STOP buttons on both the upstream and
downstream CTS850 units so that the START/STOP lights are on.
11. Verify that MS AIS alarm seconds are counted in the SDH
RESULTS display of the upstream CTS850.
12. With the downstream CTS850, verify that the displayed K1 or K2
bytes are not all zeros.
13. Press the START/STOP buttons on both the upstream and
downstream CTS850s so that the START/STOP lights are off.
14. To check the LTE response to a HP RDI alarm, change the
upstream CTS850 as follows:
Press Menu
Button
Select Menu
Page
Highlight
Parameter
Select Choice
TRANSMIT
Defects &
Anomalies
Error Rate set to
None
Transmit Alarm
set to
HP RDI
RESULTS
SDH RESULTS
none
Defects
Summary of Contents for CTS 850