Calibration-7D14
MEASUREMENT
INTERVAL
ADJUSTMENT
Equipment
Required
1.
Indicator oscilloscope
3.
Frequency standard
2.
Flexible plug-in extender
4.
Tuning tool
Control
Settings
Set
the controls as given
under Preliminary Control
Settings.
The
location of the Measurement Interval adjustment is
shown
in
Fig. 5-4.
b.
Replace the right side shield on
the unit and remove
the
left shield.
c.
Note
the Frequency
at 27°C notation on the crystal
oscillator cover (see Fig.
5-4).
d.
Place the 7D14 on the
flexible plug-in extender and
plug the extender
into the Indicator Oscilloscope.
6.
Adjust
Crystal
Oscillator
Frequency
NOTE
The
oscillator
frequency must be adjusted
at an
ambient room temperature of
about +2tfC according
to
the
following procedure
to
ensure operation within
the
limits
given
in Section
1 for an operating tempera
ture
range of 0°C
to
+50°C.
a.
Remove
the 7D14
from the Indicator Oscilloscope.
Crystal
Oscillator
Frequency
Adjustment
(Remove screw)
■■■
Fig. 5-4. Location of
Measurement Interval and Output Signal
Adjustments (on
left side of instrument).
e.
Connect the frequency standard one-megahertz out
put
to
the
CH
A INPUT.
f. Press the MEASUREMENT
INTERVAL
10
s button
and the
BW 5 MHz button.
g.
Place the
7D14 with the left side on the bench so the
crystal oscillator
is facing downward. Allow the unit to
warm
up in
this position for
about 15 minutes.
h.
CHECK-Readout
display
for a count of 1000.0000
kHz
±
one-fifth of the
5.0-MHz error indicated on the
oscillator cover ±1
count.
For
example, for an oscillator
Freq
at 27°C of 5.0 MHz +1.0
Hz,
a
count
of 1000.0000
kHz minus 0.2
Hz
±1
count
(999.9998 kHz ±1 count)
should
be obtained. If the 5.0-MHz error were —1.0
Hz, 0.2
Hz
would be added to
the count (1000.0002 kHz
±1
count).
i.
ADJUST—
Crystal
oscillator
frequency adjustment for
a
displayed
count as given in part h of this step. To gain
access
to the oscillator frequency adjustment, remove the
screw
in
the oscillator cover. The adjustment is made with
the tuning tool.
j. Disconnect all test equipment.
k. Remove the 7D14
from the plug-in extender. Replace
the
left side shield on
the unit.
5-16
®I
Summary of Contents for 7D14
Page 4: ...7D14 ...
Page 11: ...Operating Instructions 7D14 Fig 2 1 7D14 front panel controls and connectors 2 2 ...
Page 33: ... 3 13 Fig 3 11 Logic diagram for Zero Cancel Logic stage Circuit Description 7D14 ...
Page 38: ...3 18 Fig 3 16 Time Base and Control circuit detailed block diagram Circuit Description 7D14 ...
Page 44: ...NOTES ...
Page 46: ...NJ Fig 4 1 Electrode configuration for semiconductors in this instrument I ...
Page 68: ...NOTES ...
Page 96: ... 7DI 4 DIGITAL COUNTER UNIT ...
Page 98: ...GRS 0371 BLOCK DIAGRAM ...
Page 99: ......
Page 103: ...0 0 I 200 mV 500 µs 0 001 200 mV 500 µs 0 001 MHz 00 mV E 00 µs 0 001 MHz ...
Page 106: ...1 ...
Page 110: ...A2 Logic Circuit Board Assembly jQ798i 798 jc743 CR744t uni R724 R742 JL744S FrR796 ...
Page 113: ......
Page 114: ...P 0 A2 LOGIC BOARD ...
Page 121: ... A B D t F H J NPR Tj ZWX V A AC M AEA HUM qAZ DEF HJ N P R S T J V V7X y ABM APAI AA 7DI4 ...
Page 129: ......
Page 130: ...4 7D14 DIGITAL COUNTER ...