4-47
Group 16: LCD Function Parameters
Code
Parameter Name
Setting Range
Default Unit
Control Mode
Attribute
V/F SLV
PM
SLV
16-00 Main Screen Monitoring
5~82 (Parameter 12-05~12-82)
When using LCD to operate, the
monitored item displays in the first
line. (default is frequency
command)
16
-
O
O
O
*1
*6
16-01 Sub-Screen Monitoring 1
5~82 (Parameter 12-05~12-82)
When using LCD to operate, the
monitored item displays in the
second line. (default is output
frequency)
17
-
O
O
O
*1
*6
16-02 Sub-Screen Monitoring 2
5~82(Parameter 12-05~12-82)
when using LCD to operate, the
monitored item displays in the third
line. (default is output current)
18
-
O
O
O
*1
*6
16-03 Selection of Display Unit
0~39999:
Determine the display way and unit
of frequency command
0
-
O
O
O
0: Frequency display unit is 0.01Hz
1: Frequency display unit 0.01%
2: Rpm display; motor rotation
speed is set by the control
modes to select IM (02-07)/ PM
(22-03) motor poles to calculate.
3~39: Reserved
40~9999:
Users specify the format, Input
0XXXX represents the display of
XXXX at 100%.
10001~19999:
Users specify the format; Input
1XXXX represents the display of
XXX.X at 100%.
20001~29999:
Users specify the format, Input
2XXXX represents the display of
XX.XX at 100%.
30001~39999:
Users specify the format, Input
3XXXX represents the display of
X.XXX at 100%.
16-04 Selection of Engineering Unit
0: No Unit
0
-
O
O
O
*6
1: FPM
2: CFM
3: PSI
4: GPH
5: GPM
6: IN
7: FT
8: /s
9: /m
10: /h