4-88
In V / F control mode, the output current is greater than the no-load current with slip compensation is
enabled.
Note:
The value of 02-01 needs to be greater than the value set in parameter 02-00, otherwise warning
message "SE01" out of range error will be displayed.
Figure 4.3.12 Y-equivalent model of an induction motor
(13) Motor Leakage Inductance Ratio (02-33)
This parameter is set by the conversion of manual adjustment function. This adjustment does not
have the magnetic function. Normally, it does not require adjustment.
Definition of leakage inductance ratio is the ratio of leakage inductance to rotor inductance. If
default setting is 3.4%, adjust this ratio changes the parameter of motor leakage inductance. The
formula of this ratio is as follows:
Lr
LlKg
When the ratio of leakage inductance is too high or too low, it may cause the motor jittering with
different sound and without operation. The general setting range is 3.0%~5.0% and 4.0% is the
relatively common value for motor operation normally. The ratio of leakage inductance is adjusted
depending on different motor types.
(14) Motor Slip Frequency (02-34)
This parameter is set by the conversion of manual adjustment function. This adjustment does not
have the magnetic function. Normally, it does not require adjustment.
The default setting is 1Hz and the value of motor slip frequency is obtained from motor nameplate.
Take 4-pole motor with 60Hz for example,
Synchronous speed is
1800
4
60
120
120
Pole
Frequence
N
rpm and the rated speed in the
motor nameplate is 1700 rpm, then
Hz
Slip
67
.
1
60
1700
1800
.
Note:
Adjusting the motor slip frequency changes the parameter of rotor resistance and the value of slip
frequency is adjusted depending on different motor types.
Note:
After executing auto-tuning, parameters which marked <1> will renew the value. Please refer Group
17: Automatic Tuning Parameters for more detail.