4-36
Group 12: Monitoring Parameters
Code
Parameter Name
Setting Range
Default Unit
Control Mode
Attribute
V/F SLV
PM
SLV
12-00
Display Screen Selection
(LED)
00000~77777
From the leftmost bit, it displays the
screen when press DSP key in
order.
0: No display
1: Output Current
2: Output Voltage
3: DC Bus Voltage
4: Heatsink Temperature
5: PID Feedback
6: AI1 Value
7: AI2 Value
00321
-
O
O
O
*1
*5
12-01
PID Feedback Display Mode
(LED)
0: Display the Feedback Value by
Integer (xxx)
0
O
O
O
*5
1: Display the Feedback Value by
the Value with First Decimal
Place (xx.x)
2: Display the Feedback Value by
the Value with Second Decimal
Place (x.xx)
12-02
PID Feedback Display Unit
Setting (LED)
0: xxxxx (no unit)
0
O
O
O
*5
1: xxxPb (pressure)
2: xxxFL (flow)
12-03 Line Speed Display (LED)
0~60000
1500/
1800
RP
M
O
O
O
*5
12-04
Line Speed Display Mode
(LED)
0: Display Inverter Output
Frequency
0
O
O
O
*1
*5
1: Line Speed Display at
Integer.(xxxxx)
2: Line Speed Display at One
Decimal Place. (xxxx.x)
3: Line Speed Display at Two
Decimal Places. (xxx.xx)
4: Line Speed Display at Three
Decimal Places. (xx.xxx)
Summary of Contents for F510 Series
Page 1: ......
Page 434: ...11 10 Dimensions of LED LCD keypad IP20 Figure 11 5 2 Dimensions of LED keypad ...
Page 444: ...Ver 02 2019 09 ...